Fluke 572-2 High Temperature Infrared Thermometer

Fluke 572-2 High Temperature Infrared Thermometer

Sale price  Rs. 101,920.00 Regular price  Rs. 127,400.00
Skip to product information
Fluke 572-2 High Temperature Infrared Thermometer

Fluke 572-2 High Temperature Infrared Thermometer

Why to Choose ?
✔ Ideal for high-temperature industrial environments (metal, glass, cement, power plants)
✔ Enables safe distance measurement of extremely hot surfaces
✔ Combines IR + contact measurement for maximum flexibility
✔ High precision even for small targets at long distances
✔ Suitable for continuous monitoring and analysis (data logging)
✔ Rugged and reliable for harsh working conditions

-20% Rs. 101,920.00
M.R.P.: Rs. 127,400.00
Inclusive of all taxes
Product Overview
Key Features
Specifications
Accessories

The Fluke 572-2 is a high-temperature infrared thermometer built for extreme industrial environments. With the ability to measure up to 900°C and a powerful 60:1 distance-to-spot ratio, it enables accurate temperature readings from a safe distance. It also supports K-type thermocouple input, making it a versatile solution for both non-contact and contact temperature measurements in demanding applications.

  • Temperature range: -30°C to 900°C (-22°F to 1652°F)
  • Accuracy: ±1°C or ±1% of reading
  • 60:1 distance-to-spot ratio for long-range precision
  • Dual laser targeting for accurate measurement
  • Supports K-type thermocouple input
  • Displays IR + contact temperature simultaneously
  • Adjustable emissivity with built-in material table
  • Stores up to 99 data points
  • Hi/Lo alarms (audible + visual)
  • Displays Min / Max / Avg / Difference
  • Multi-language interface
  • USB connectivity for data transfer

Infrared Measurement

Range: -30°C to 900°C (-22°F to 1652°F)

Accuracy:
≥ 0°C: ±1°C or ±1%
-10°C to 0°C: ±2°C
< -10°C: ±3°C

Repeatability: ±0.5% or ±0.5°C
Optical Resolution: 60:1
Minimum Spot Size: 19 mm
Response Time: < 500 ms
Spectral Response: 8 to 14 µm
Emissivity: 0.10 to 1.00 (adjustable)

Contact Measurement (Thermocouple)

Type: K-type
Range: -270°C to 1372°C
Accuracy: ±1% or ±1°C (typical)
Resolution: 0.1°C / 0.1°F

Data & Features

Memory: 99 readings
Display: Dot matrix with backlight
Interface: USB 2.0
Alarms: Audible + visual Hi/Lo

General Specifications

Power: 2 × AA batteries

Battery Life:
~8 hours (laser + backlight ON)
Up to 100 hours (OFF)
Weight: 0.322 kg
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 60°C
Humidity: 10% to 90% RH
Safety: IEC 60825-1, IEC 61326-1

K-type thermocouple bead probe
Durable hard case
USB 2.0 computer interface cable